Special Features

  • Precision ball bearing.
  • Full extension of drawer.
  • Load capacity STDS(I)45=45Kgs.
                           STDS(I)35=35Kgs.
  • Direct fitting from front.
  • Removable drawer with Latch
  • System 32 installation.

 

Specifications

Code No. Length
(mm)
Extension
(mm)
Gap/Side (mm) Max. Load
Kgs.
Finish
STDS 25 (I) 45 STDS 25 (I) 35 250 260 12.7

to

13.0
45/35 White, Black, MG Gray Zinc Plated
STDS 30 (I) 45 STDS 30 (I) 35 300 310
STDS 35 (I) 45 STDS 35 (I) 35 350 360
STDS 40 (I) 45 STDS 40 (I) 35 400 410
STDS 45 (I) 45 STDS 45 (I) 35 450 460
STDS 50 (I) 45 STDS 50 (I) 35 500 510
STDS 55 (I) 45 STDS 55 (I) 35 550 560
STDS 60 (I) 45 STDS 60 (I) 35 600 610
STDS 75 (I) 45 STDS 75 (I) 35 750 760
STDS 90 (I) 45 STDS 90 (I) 35 900 910

 

Fitting Instructions

  1. To install sleek telescopic drawer slide 12.7 to 13.0mm gap per side is required between cabinet and drawer. (Refer Fig. 1)
  2. Depress latch and remove the inner slide. (Refer Fig. 2)
  3. Fit outer (fixed) slide onto the inside of the cabinet, access to holes can be got through slots in intermediate slide.
  4. Slides should be fitted parallel and screws tightened fully to avoid gaps.
  5. Fit inner slide onto the outside of the drawer.
  6. Now slide the drawer with inner slide fitted on to the intermediate slides on the cabinet till the latch will automatically engage.
     

Drilling Diagram for Cabinet

 
 
 

Caution

For efficiency and durability,

  1. Strictly maintain 12.7 to 13.0mm side gap.
  2. Fit slides parallel and at equal heights.
  3. Do not apply paint or polish.
  4. Do not let saw dust enter into the slides.